Specifications | Range | Accuracy |
DC voltage | 60mV/600mV/6V/60V/600V | ±(0.7%+3) |
1000V | ±(0.8%+2) | |
AC voltage | 60mV/600mV/6V/60V/600V | ±(0.8%+3) |
750V | ±(1%+4) | |
DC current | 60A/600A/1000A | ±(2.5%+6) |
AC current | 60A/600A/1000A | ±(2.5%+6) |
Resistance | 600Ω/6KΩ/60 KΩ/600 KΩ/6MΩ | ±(0.8%+3) |
60MΩ | ±(1.2%+3) | |
Capacitance | 10nF/100nF/1000nF/10μF/100μF/1000μF/10mF/100mF | ±(4.0%+5) |
Frequency(from clamp) | 0~10KHz | ±(1.5%+5) |
Frequency(AC voltage) | 0~10KHz | ±(1.5%+5) |
Logic frequency | 0~10MHz | ±(0.5%+3) |
Duty cycle | 10%~90% | ±3.0% |
Features: | ||
Display | Counts | 6000 |
Jaw opening | Φ40mm/1.6" | |
Auto ranging | √ | |
Manual ranging | √ | |
Auto power off | √ | |
REL | Relative measurement | √ |
Diode | 2.7V | √ |
Continuity buzzer | <50Ω | √ |
MAX/MIN | √ | |
Data hold | √ | |
Low battery display | √ | |
Display backlight | √ | |
Work light | √ | |
True RMS | True root mean square measurement | √ |
NCV | Non-contact voltage detector | √ |
Inrush | Inrush current measurement | √ |
General | ||
Power Supply | 1x9V 6F22 batterY | |
Product Size | 238*92*50mm/9.37"x3.6"x1.9" | |
Product Weight | 386g/0.85lb | |
Safety Rating | CE CAT.III 1000V RoHS |